 APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER.   OPERATING CONDITION:  THE MAX.ADMISSIBLE PRESSURE 1.6MPa RESISTING WATER TEMPERATURE OF 50℃   SPECIALITY: *SEMI-POSITIVE ROTARY PISTON TYPE * STRIGHT READING REGISTER  *SHIELED MAGNETIC TRANSMISSION                 * INSTALLATION IN ANY POSITION * ROBUST AND RUGGED CONSTRUCTION 
Maximum permissible error:
 Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class C. 
  FLOW-ERROR CURVE   SPECIFICATION AND OVERAL DIMENSIONS
 
 
| Description | Unit | Hydraulic data and dimensions |  
| Nominal size | mm(inch) | DN15(1/2) |  
| Overload flow-rate (qs) | m3/h | 1.2 |  
| Permanent flow-rate (qp) | m3/h | 0.6 |  
| Transitional flow-rate (qt) | l/h | 9 |  
| Minimum flow-rate (qmin) | l/h | 6 |  
| Start flow-rate | l | ≤2 |  
| Min. reading | l | 0.005 |  
| Max. reading | m3/h | 9999.99999 |  
| Max. working pressure | MPa | 1.0 |  
| △P at the qs | MPa | ≤0.1 |  
| L | mm | 204 |  
| I | mm | 110 |  
| B | mm | 80 |  
| H | mm | 95 |  
| Weight | Plastic body with connections  | Kg | 0.53 |  
| Plastic body without connections  | 0.29 |  
| Stainless body with connections  | 0.94 |  
| Stainless body without connections  | 0.70 |  OVERALL DIMENSIONS                                              PRESSURE LOSS CURVE
 
  |