 APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER   OPERATING CONDITION:  THE MAX.ADMISSIBLE PRESSURE 1.6MPa RESISTING WATER TEMPERATURE OF 50℃   SPECIALITY: *SEMI-POSITIVE ROTARY PISTON TYPE * STRIGHT READING REGISTER  *MAGNETIC TRANSMISSION AND WITH MAGNETIC SHIELD                 * INSTALLATION IN ANY POSITION * ROBUST AND RUGGED CONSTRUCTION
   Maximum permissible error: Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class C.   FLOW-ERROR CURVE 
SPECIFICATION AND OVERALL DIMENSIONS
 
| DESCRTPTION | UNIT | Hydraulic data and dimensions  |  
| Nominal size | mm(inch) | DN15(1/2)  |  
| Overload flow-rate (qs) | m3/h  | 3 |  
| Permanent flow-rate (qp) | m3/h  | 1.5 |  
| Transitional flow-rate (qt) | l/h  | 22.5 |  
| Minimum flow-rate (qmin) | l/h  | 15 |  
| Min. reading  | 1 | 0.05 |  
| Max. reading  | m3 | 99999.9999 |  
| Max. working pressure | MPa | 1.6 |  
| △P at qs | MPa | 0.086 |  
| I | mm | 245/270 |  
| L | mm | 165/190 |  
| B | mm | 100 |  
| R | inch | R1/2 |  
| G | inch | G3/4B |  
| H | mm | 122 |  
| Weight | Without connections | kg | 0.60 |  
| With connections | 0.77 |  OVERALL DIMENSIONS                                                           PRESSURE LOSS CURVE
 
  |