 Model CD74TRP-E is an inferential, single stream, straight reading type meter for cold water, and it’s suitable for domestic use. The sealed register mechanism, which is filled with special liquid, is equipped with a suitable pressure compensating device. Brass body and adopt all antiseptic material, no leak. It has all the advantages which the wet or dry dial water meters possess.   WORKING CONDITION: *The max. admissible water pressure:1.6MPa(16bar) *Water temp.:not more than 50℃ Maximum permissible error:
 Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class B.
 FLOW-ERROR CURVE
  SPECIFICATION AND OVERAL DIMENSIONS
 
| Description | Unit | Hydraulic data and dimensions  |  
| Nominal size  | mm | 15 | 20 | 25 |  
| inch | 1/2 | 3/4 | 1 |  
| Overload flow-rate (qs) | m3/h | 3 | 5 | 7 |  
| Permanent flow-rate (qp) | m3/h | 1.5 | 2.5 | 3.5 |  
| Transitional flow-rate (qt) | m3/h | 0.12 | 0.2 | 0.28 |  
| Minimum flow-rate (qmin) | m3/h | 0.03 | 0.05 | 0.07 |  
| Max. reading  | m3 | 99999.9999 | 99999.9999 | 99999.9999 |  
| Min. reading | m3 | 0.00005 | 0.00005 | 0.00005 |  
| Max. working pressure  | MPa | 1.6 | 1.6 | 1.6 |  
| ΔP at the qs  | MPa | ≤0.1 | ≤0.1 | ≤0.1  |  
| L | mm | 110 | 130 | 160 |  
| I | mm | 190 | 230 | 280 |  
| H | mm | 89 | 89 | 89 |  
| B  | mm | 88 | 88 | 88 |  OVERALL DIMENSIONS                                                                            PRESSURE LOSS CURVE
  |