 APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER,IT'S SUITABLE FOR DOMESTIC USE. WORKING CONDITION: THE MAX.ADMISSIBLE WATER PRESSURE: 1.6MPa. WATER TEMPERATURE: UP TO 50℃ SPECIALITY: *LARGE MEASURING RANGE, HIGH FLOW ACCURACY. *STEADY ERROR CURVE. *PLASTIC BODY AND LONG SERVICE LIFE  *RELIABLE OPERATION. *MAGNETIC SHIELD PROTECTION. *NEGLIGIBLE HEAD LOSS AT WORKING FLOW – RATES. *SEALED REGISTER WITHOUT ANY CONDENSATION PROBLEM. 
Maximum permissible error:
 Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class B.FLOW-ERROR CURVE 
  
 SPECIFICATION AND OVERALL DIMENSIONS 
| Description | Unit | Hydraulic data and dimensions |  
| Nominal size  | mm | 15 |  
| inch | 1/2 |  
| Overload flow-rate (qs) | m3/h | 3 |  
| Permanent flow-rate (qp) | m3/h | 1.5 |  
| Transitional flow-rate (qt) | l/h | 120 |  
| Minimum flow-rate (qmin) | l/h | 30 |  
| Min. reading | l | 0.05 |  
| Max. reading | m3 | 99999 |  
| Nominal pressure | MPa | 1.6 |  
| ΔP at the qs | MPa | 0.08 |  
| L | mm | 110 |  
| I | mm | 190 |  
| H | mm | 86 |  
| B | mm | 81 |  
| Weight | Without connections | Kg | 0.32 |  
| With connections | 0.49 |  OVERALL DIMENSIONS                                                                  PRESSURE LOSS CURVE
 
  |