 DS78TBR-E/S is an inferential, multi-stream, wet dial, straight reading type meter for cold water, and it’s Suitable for domestic use. Body and Internal mechanisms are made from wear-resistant, waterproof, antimagnetic and antiscaling plastic material. No leak, mechanical transmission not effected by external magnetic fields or ferrous particles in water.   SPECIALITY: * Internal filter of adequate filtering section. * Large measuring range and high flow accuracy * Low start-up flow, high sensitivity, long life of service time.   WORKING CONDITION: * The max. admissible pressure: 1.6MPa(16bar) * Resisting water temperature of  50℃ Maximum permissible error:
 Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class B. FLOW-ERROR CURVE SPECIFICATION AND OVERAL DIMENSIONS
 
| Description | Unit | Hydraulic data and dimensions |  
| Nominal size | mm | 15 | 20 |  
| inch | 1/2 | 3/4 |  
| Overload flow-rate (qs) | m3/h | 3 | 5 |  
| Permanent flow-rate (qp) | m3/h | 1.5 | 2.5 |  
| Transitional flow-rate (qt) | l/h | 120 | 200 |  
| Minimum flow-rate (qmin) | l/h | 30 | 50 |  
| Min. reading | l | 0.05 | 0.05 |  
| Max. reading  | m3 | 99999.9999 | 99999.9999 |  
| Nominal pressure | MPa | 1.6 | 1.6 |  
| ΔP at the qs  | MPa | ≤0.10 | ≤0.10 |  
| L | mm | 165 | 190 |  
| I | mm | 245 | 290 |  
| H  | mm | 116 | 116 |  
| B  | mm | 100 | 100 |  
| G  | Inch  | G3/4B | G1B |  
| R | Inch  | R1/2 | R3/4 |  OVERALL DIMENSIONS                                                        PRESSURE LOSS CURVE
 
  |