 APPLICATION:MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER SPECIALITY: * ADVANTAGE OF BURGLARPROOF  * THE SPECIAL STRUCTURE OF THE BURGLARPROOF CAP AND THE BURGLARPROOF TIGHTING RING * HIGH ACCURACY AND LARGE MEASURING RANGE * NEGLIGIBLE HEAD LOSS AT WORKING FLOW-RATE  * MAGNET DRIVE WITH ANTI-MAGNETIC  * HIGH-QUALITY MATERIAL WITH LONG LIFE OF SERVICE * RELIABLE IN DATA COLLECTING , HERMETICALLY SEALED REGISTER * REMOTE READING SYSTEM, RELIABLE IN DATA COLLECTING. * ELECTRIC UNIT WITH DOUBLE REED SWITCHE SIGNALS SENSOR SIGNAL STABILITY AND ANTI-MAGNETIC. WORKING CONDITION: * THE MAX. ADMISSIBLE WATER PRESSURE: 1.6MPA * WATER TEMPERATURE: WATER TEMP. UP TO 50℃ Maximum permissible error: Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class B.
 FLOW-ERROR CURVE
  SPECIFICATION AND OVERAL DIMENSIONS
 
| Description | Unit | Hydraulic data and dimensions  |  
| Nominal size  | mm | DN15  | DN20  | DN25  |  
| inch | 1/2 | 3/4 | 1 |  
| Overload flow-rate (qs) | m3/h | 3 | 5 | 7 |  
| Permanent flow-rate (qp)  | m3/h | 1.5 | 2.5 | 3.5 |  
| Transitional flow-rate (qt)  | l/h | 120 | 200 | 280 |  
| Minimum flow-rate (qmin)  | l/h | 30 | 50 | 70 |  
| Min. reading | l | 0.05 | 0.05 | 0.05 |  
| Max. reading | m3 | 99999.9999 | 99999.9999 | 99999.9999 |  
| Max. working pressure | MPa | 1.6 | 1.6 | 1.6 |  
| ΔPmax at qs  | MPa | ≤0.1 | ≤0.1 | ≤0.1 |  
| L | mm | 165 | 190 | 190 | 260 |  
| G | inch | G 3/4B | G1B | G1 1/4B |  
| I | mm | 245 | 270 | 290 | 380 |  
| B | mm | 81 | 81 | 94 |  
| h | mm | 103 | 104 | 119 |  
| H | mm | 171 | 172 | 189 |  
| Weight | Without connections | Kg | 0.986 | 1.15 | 1.7 |  
| with connections | Kg | 1.017 | 1.181 | 1.731 |  OVERALL DIMENSIONS                                                      PRESSURE LOSS CURVE
 
  |